Parathyroid imaging: the importance of pinhole collimation with both single- and dual-tracer acquisition
William C Klingensmith1, Phillip J Koo, Adam Summerlin
1Division of Nuclear Medicine, Department of Radiology, University of Colorado School of Medicine, Aurora, CO 80113, USA. william.klingensmith@ucdenver.edu
Unlabelled:
Our objective was to rigorously compare pinhole and parallel-hole collimation in an intrapatient, intrastudy design in 2 parathyroid imaging protocols: the first was dual-phase (99m)Tc-sestamibi imaging, and the second was dual-phase (99m)Tc-sestamibi plus dual-tracer ((99m)Tc-sestamibi and (123)I) simultaneous-acquisition subtraction imaging.
Methods:
Thirty-three patients with 37 surgically proven nonectopic parathyroid adenomas were evaluated. Anterior pinhole and parallel-hole images of the neck were available for (99m)Tc-sestamibi at 15 min and 3 h, and for simultaneously acquired (99m)Tc-sestamibi and (123)I subtraction at 15 min, all from a single study. The images were modified so that all had a square border and so that the thyroid filled approximately three quarters of the image. The images were evaluated by 2 experienced nuclear medicine physicians who did not know the surgical results or whether the images were acquired with pinhole or parallel-hole collimation. The observers indicated the location of any identified adenoma and graded the certainty of diagnosis on a 3-point scale.
Results:
The localization success rate for the 2 observers combined for the single-tracer dual-phase images was 66.2% with pinhole collimation and 43.2% with parallel-hole collimation (P < 0.0001). The localization success rate with the addition of the dual-tracer simultaneous-acquisition subtraction image was 83.8% with pinhole collimation and 62.2% with parallel-hole collimation (P = 0.0018). In addition, the degree of certainty of localization was greater with pinhole collimation with both imaging protocols (P < 0.001 in both cases).
Conclusion:
In the anterior projection, pinhole collimation is superior to parallel-hole collimation for parathyroid imaging with either dual-phase (99m)Tc-sestamibi or dual-phase (99m)Tc-sestamibi plus dual-tracer ((99m)Tc-sestamibi and (123)I) simultaneous-acquisition subtraction.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
05:41Synchronous Triplanar Reconstruction Integrated with Color Doppler Mapping for Precise and Rapid Localization of Thyroid Lesions
Published on: February 9, 2024
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...