Introduction:
There has been continuing interest in the development and use of esthetic and effective orthodontic archwires. The aims of this study were to evaluate the inner alloy core dimensions of 4 brands of as-received esthetic coated wires and their mechanical properties before and after 21 days of oral exposure, compared with conventional stainless steel and nickel titanium wires.
Methods:
Four groups (Ortho Organizers, Carlsbad, Calif; TP Orthodontics, LaPorte, Ind; Orthometric, Beijing, China; and Trianeiro, Rio Claro, São Paulo, Brazil) of orthodontic archwires were tested. Five properties were evaluated: inner wire dimensions, modulus of elasticity, modulus of resilience, maximum deflection force, and load deflection curve characteristics. Images of the transverse sections from the specimens were made with a stereoscope. The inner alloy core dimensions of each wire were measured by using Image Pro Plus software (version 4.5; Media Cybernetics, Silver Spring, Md). All specimens were tested in a universal testing machine in a 3-point bending test.
Results:
Coated wires of the Ortho Organizers and Trianeiro groups showed greater reductions in their inner alloy core dimensions and produced lower loading and unloading forces and lower modulus of elasticity, modulus of resilience, and maximum deflection force values than did their control wires. Inner alloy core dimensions and the mechanical behavior of coated wires practically did not differ from the control wires in the TP Orthodontics and Orthometric groups.
Conclusions:
The reduction on the inner alloy core dimensions to compensate for the coating thickness seems to be the variable responsible for greater changes in the mechanical properties of esthetic coated wires.
More Related Videos
Related Concept Videos
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55 °C.
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used to...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Torsion of Noncircular Members