Related Experiment Video
Updated: May 12, 2026

Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
Outcome of concomitantCox-maze III procedure using an argon-based cryosurgical system: a single-center experience
Bobby Yanagawa1, Sari D Holmes, Linda Henry
1Inova Heart and Vascular Institute, Cardiac Surgery Research, Falls Church, VA 22042, USA.
Background:
The Cox-Maze procedure (CM) for atrial fibrillation (AF) is associated with a high rate of sinus restoration. This study assessed the safety and efficacy of concomitant CM using an argon-based cryosurgical platform only.
Methods:
Data were collected prospectively for 250 consecutive patients undergoing concomitant cryosurgical CM. We examined baseline characteristics, perioperative and postoperative outcomes, health-related quality of life (Medical Outcomes Trust SF-12 Health Survey and AF Symptom Checklist) and Kaplan-Meier survival analysis.
Results:
Mean age was 64.3 ± 12.1 years, AF duration was 35.7 ± 54.2 months, left atrial size was 5.2 cm (range, 3.1 to 11.0 cm; 16.8% > 6 cm), 86% had nonparoxysmal AF, with history of cardioversion in 32% and catheter ablation in 8%. Concomitant procedures were mitral valve operation in 69.6%, coronary artery bypass graft in 29.2%, aortic valve replacement in 22.0%, with 46% multiple concomitant procedures and 16% with a previous cardiac operation. Perioperative outcomes were 5 deaths (2%), 3 strokes (1%), 1 transient ischemic attack (<1%), and 4 pacemakers for sinus node dysfunction (2%). There were no late thromboembolic events (mean follow-up, 28.2 ± 23.7 months), and 11% were taking warfarin for atrial arrhythmia at 1 year. Significant improvement in health-related quality of life (p < 0.001) was noted. At 24 months, 92.4% of patients were in sinus rhythm; with 82.8% in sinus rhythm off antiarrhythmic drugs. Two-year cumulative survival was 91%.
Conclusions:
The cryosurgical CM procedure can be performed safely and effectively as defined by the low number of postoperative morbidities, high return to sinus rhythm off antiarrhythmic drugs, and low rate of thromboembolic events, with most patients off anticoagulation by 2 years.