Activity measurement of gamma-ray emitters in aerosol filters exposed in Lithuania, in March-April 2011
A Gudelis1, I Gorina, T Nedveckaitė
1Center for Physical Sciences and Technology, Ionizing Radiation Metrology Laboratory, Savanorių Ave. 231, LT-02300 Vilnius, Lithuania. microbq@hotmail.com
Abstract:
Two aerosol sampling stations in Lithuania were simultaneously used for assessing consequences of the accident at the Fukushima Dai-ichi nuclear power plant. The maximum activity concentrations of (129 m)Te, (131)I, (134)Cs and (137)Cs were 0.59 ± 0.06, 3.5 ± 0.3, 0.90 ± 0.08, 0.90 ± 0.07 mBq m(-3) at station #1 in Vilnius, and 0.29 ± 0.03, 1.0 ± 0.1, 0.41 ± 0.04, 0.41 ± 0.0 4 mBq m(-3) at station #2 in northeastern part of Lithuania, respectively.
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Biological Effects of Radiation
Atomic Emission Spectroscopy: Lab