Related Experiment Video
Updated: May 12, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Delayed intrinsicoid deflection onset in surface ECG lateral leads predicts left ventricular reverse remodeling after
Freddy Del-Carpio Munoz1, Brian D Powell, Yong-Mei Cha
1Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota 55905, USA.
Background:
Up to one-third of the patients who undergo cardiac resynchronization therapy (CRT) are not responders.
Objective:
To demonstrate that delayed lateral left ventricular activation time determined through time to intrinsicoid deflection onset (ID) predicts response after CRT.
Methods:
The ID in leads I, aVL, V₁ and V₂, and V₅ and V₆ were measured in 135 patients who underwent CRT. A CRT response was defined as a decrease in left ventricular end-systolic volume (LVESV) exceeding 15% at 6 months.
Results:
In patients with left bundle branch block or nonspecific intraventricular conduction delay, response was predicted by longer ID in lead I (odds ratio [OR] 3.23; 95% confidence interval (CI) 1.4-7.4; per 20-ms increase), in lead aVL (OR 3.0; 95% CI 1.2-7.3; per 20-ms increase), and in lead I minus lead V₁ (OR 2.4; 95% CI 1.2-4.7) adjusting for baseline QRS duration and LVESV. Results were similar after adjusting for postimplant or change in QRS duration. The ID parameters were better predictors of response than QRS duration parameters. ID in lead I/QRS duration ratio (OR 3.1; 95% CI 1.6-5.9) also increased the odds of response after adjusting for baseline LVESV. Cutoff values for ID in leads--I, 110 ms; aVL, 130 ms; I minus V₁, 90 ms--and ID in lead I/QRS duration ratio of 0.69 yielded a sensitivity and a specificity as high as 83% and 81%.
Conclusions:
Measurement of ID on surface electrocardiography permits a preimplant, noninvasive means of determining left ventricle activation delay; is a good predictor of CRT response; and represents a promising alternative to QRS duration parameters.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...