Volume expansion does not alter cerebral tissue oxygen extraction in preterm infants with clinical signs of poor

Elisabeth M W Kooi1, Michelle E van der Laan, Elise A Verhagen

  • 1Division of Neonatology, Beatrix Children's Hospital, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. e.kooi@umcg.nl

Neonatology
|April 4, 2013
PubMed

Insights

Volume expansion does not improve cerebral perfusion in preterm infants with poor perfusion signs. Cerebral fractional tissue oxygen extraction (cFTOE) remained unchanged, indicating that cerebrovascular autoregulation (CAR) is likely present or the intervention is insufficient.

Area of Science:

  • Neonatalogy
  • Pediatric Critical Care
  • Medical Physiology

Background:

  • Preterm infants with poor perfusion often receive volume expansion.
  • Evidence for volume expansion's effect on cerebral perfusion in neonates is limited.
  • Cerebrovascular autoregulation (CAR) may influence the response to volume expansion.

Purpose of the Study:

  • To evaluate the impact of volume expansion on cerebral fractional tissue oxygen extraction (cFTOE).
  • To assess changes in cerebral perfusion in preterm infants experiencing poor perfusion.

Main Methods:

  • Observational study using near-infrared spectroscopy to measure cFTOE.
  • Simultaneous measurement of mean arterial blood pressure (MABP).
  • Multi-level analyses to assess the effects of volume expansion on cFTOE and MABP.

Main Results:

  • Volume expansion led to a small increase in MABP but no significant change in cFTOE.
  • No subgroup with absent CAR was identified.
  • The study included 14 preterm infants with a median gestational age of 26.7 weeks.

Conclusions:

  • Volume expansion does not enhance cerebral perfusion in preterm infants with poor perfusion.
  • Cerebral perfusion, assessed by cFTOE, is not improved by volume expansion.
  • The findings suggest intact CAR or inadequate volume expansion in these infants.
Abstract

Related Concept Videos

Assessment of Diffusion and Perfusion01:17

Assessment of Diffusion and Perfusion

Understanding and evaluating diffusion and perfusion is critical in assessing a patient's respiratory and circulatory health. These processes play key roles in maintaining the body's internal environment, ensuring that tissues receive adequate oxygen while waste products are efficiently removed.
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Atelectasis II: Pathophysiology01:10

Atelectasis II: Pathophysiology

Atelectasis develops when alveoli lose their air and collapse inward. Because lung tissue is naturally elastic, these air sacs shrink rather than remaining open. Collapsed alveoli are no longer ventilated, reducing their role in gas exchange. Blood flow may continue in these regions, creating a ventilation–perfusion mismatch. Clinical findings include decreased breath sounds, dullness to percussion, reduced chest expansion, and decreased tactile fremitus as sound transmission through collapsed...
Oxygen Transport in the Blood01:27

Oxygen Transport in the Blood

Hemoglobin (Hb) is a crucial molecule in the human body, consisting of four polypeptide chains, each bound to an iron-containing heme group. This unique structure enables hemoglobin to bind to oxygen, with each molecule capable of combining with four molecules of oxygen, leading to rapid and reversible oxygen loading. When fully loaded with oxygen, it is called oxyhemoglobin, while hemoglobin that has released oxygen is called reduced hemoglobin or deoxyhemoglobin. As hemoglobin binds oxygen,...