Related Experiment Video
Updated: May 12, 2026

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
Published on: October 24, 2018
Initial experience with single-vessel cannulation for venovenous extracorporeal membrane oxygenation in pediatric
Sara C Fallon1, Lara S Shekerdemian, Oluyinka O Olutoye
1Michael E. DeBakey Department of Surgery, Texas Children's Hospital Fetal Center, Baylor College of Medicine, Houston, TX, USA.
Objectives:
Venovenous extracorporeal membrane oxygenation has been used to provide cardiopulmonary support in critically ill infants and children. Recently, dual-lumen venovenous extracorporeal membrane oxygenation has gained popularity in the pediatric population. Herein, we report our institutional experience using a bicaval dual-lumen catheter for pediatric venovenous extracorporeal membrane oxygenation support, which has been our unified approach for venovenous extracorporeal membrane oxygenation since 2009.
Design:
This study is a retrospective review.
Setting:
The setting is a tertiary children's hospital in a major metropolitan area.
Patients:
Between 2009 and 2011, 11 patients were cannulated using a dual-lumen bicaval venous catheter. Patient demographics, cannulation details, circuit complications, complications of catheter use, and patient outcomes were collected from a retrospective chart review.
Interventions:
None.
Measurements And Main Results:
Eleven of the patients were cannulated for venovenous extracorporeal membrane oxygenation using the dual-lumen bicaval cannula. The median age at the time of venovenous cannulation was 1.9 years (range, 0.14-17.1), and the median weight was 10.2 kg (range, 3-84). Three patients (27%) required conversion to venoarterial extracorporeal membrane oxygenation. The median duration of extracorporeal membrane oxygenation support was 10 days (2-38 days). Fifty-five percent of patients suffered from a bleeding complication (disseminated intravascular coagulation, pulmonary hemorrhage, or intraventricular hemorrhage), and 45% had a circuit complication. Adequate flow rates were achieved in all patients. The overall hospital mortality in the series was 55%. There were no cannula-related complications.
Conclusions:
This review presents the first single-institution experience with the dual-lumen Avalon cannula in pediatric patients. Preliminary results indicate that the catheter can be safely placed and has an acceptable complication profile; however, continued study within larger trials is necessary to fully ascertain the clinical profile of this catheter.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...