[A cone-beam computed tomography study of changes in canal isthmus of maxillary first premolars before and after
Li-na Zhu1, Wen-hao Qian, Jin Hong
1Department of VIP Dentistry, Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai 200011, China. nalizhu@yahoo.cn
Purpose:
To analyze the difference of the incidence and type of root canal isthmus in maxillary first premolars with single root and two canals before and after instrumentation using cone-beam computed tomography(CBCT), and investigate the application and effect of CBCT in analysis of root canal isthmus.
Methods:
Sixty-six extracted maxillary first premolar with single root and two canals were scanned by CBCT before and after instrumentation. The incidence and type of isthmus before and after instrumentation were recorded and compared. The data was subjected to X(2) test and rank sum test with SPSS13.0 software package.
Results:
The incidence of isthmus was different at each 1 mm level within apical 0-6 mm in maxillary first premolar with single root and two canals before and after instrumentation (P<0.05), which was lowest at apical 1 mm and highest at apical 6 mm; the proportion of partial isthmus (PI) was significantly higher than complete isthmus (CI) (P<0.05). After instrumentation, the incidence of isthmus in apical 0-6 mm decreased (P<0.05), but the proportion of CI increased.
Conclusions:
The difference of root canal isthmus structure before and after instrumentation can be defined accurately with CBCT. CBCT is an ideal method to evaluate root canal isthmus.
More Related Videos
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Related Concept Videos
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrument Transformers