Fill volume as an indicator of surface heterogeneity in glass vials for parenteral packaging

Nathan W Kucko1, Tim Keenan1, Aisling Coughlan1

  • 1Kazuo Inamori School of Engineering, Alfred University, Alfred, New York 14802.

Related Concept Videos

Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volume of Distribution01:20

Volume of Distribution

The apparent volume of distribution (Vd) is a crucial pharmacokinetic parameter representing the hypothetical body fluid volume into which a drug disperses. It is calculated based on the total amount of drug in the body (estimated from the administered dose and bioavailability) divided by the plasma drug concentration. The total amount of drug in the body does not directly refer to the dose given but is derived by accounting for absorption, distribution, metabolism, and excretion processes.
Drug Distribution: Volume of Distribution01:25

Drug Distribution: Volume of Distribution

The volume of distribution refers to the theoretical volume necessary to contain the entire amount of an administered drug at the same concentration observed in the blood plasma. The body's intracellular fluid compartment, which makes up two-thirds of the total body water, is contrasted with the extracellular fluid compartment—comprising plasma and interstitial fluid—that accounts for one-third. The volume of distribution can vary depending on the characteristics of the drug.
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance00:56

One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance

Clearance is a key pharmacokinetic parameter that quantifies the volume of body fluid from which a drug is entirely removed within a specific time frame. It is crucial in assessing how a drug is eliminated from the body and has critical clinical applications.
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Volatilization01:10

Volatilization

Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
Total Voids in Concrete01:12

Total Voids in Concrete

Total voids in concrete encompass gel water volume, capillary pores, and entrapped air. Gel water (retained within the cement hydration products) and physically entrapped or adsorbed water are significant for the hydration process. For complete hydration, it's estimated that the space needed for the products of a cubic centimeter of cement doubles. Capillary pores constitute the unoccupied space within the hydrated cement paste, with their size largely influenced by the water-to-cement ratio...