Related Experiment Video
Updated: May 12, 2026

Measuring the Motor Aspect of Cancer-Related Fatigue using a Handheld Dynamometer
Published on: February 20, 2020
Quantifiable tests for cervical myelopathy; 10-s grip and release test and 10-s step test: standard values and aging
Yasutsugu Yukawa1, Hiroaki Nakashima, Keigo Ito
1Department of Orthopedic Surgery, Chubu Rosai Hospital, Komei 1-10-6, Minato-ku, Nagoya, Aichi 455-8530, Japan. yukawa.ort@chubuh.rofuku.go.jp
Purpose:
The 10-s grip and release (G&R) test and 10-s step test were reported to be useful tools to evaluate the severity of cervical myelopathy quantitatively. The purpose of this study is to establish the standard values of the 10-s G&R test and 10-s step test as quantitative tests for cervical myelopathy and to elucidate the aging variation and gender difference of those values in a large cohort of normal subjects.
Methods:
A total of 1230 healthy volunteers were enrolled. They included at least 100 men and 100 women in each decade from the 20s to 70s. Three tests were performed: the number of finger grips and releases in 10 s, number of steps in 10 s, and gripping power.
Results:
The average number of G&Rs on the weaker side was 21.5 ± 5.5, whereas the average number of steps was 19.7 ± 3.4. The average gripping power on the weaker side was 29.5 ± 9.6 kg. The number of G&Rs and steps in 10 s decreased significantly with age (r = -0.58, -0.43, respectively). The average number of G&Rs on the weaker side was <20 in the 60s and 70s. The number of G&Rs was significantly correlated with the number of steps and gripping power. A significant difference was seen between the genders in all three tests.
Conclusion:
The standard values of the 10-s G&R test, 10-s step test, and gripping power were established in this study. When these quantifiable tests are used as screening tests of cervical myelopathy, aging variation and gender difference should be considered.