Related Experiment Video
Updated: May 12, 2026

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Biomechanical loading of the shoulder complex and lumbosacral joints during dynamic cart pushing task
Ashish D Nimbarte1, Yun Sun, Majid Jaridi
1Department of Industrial and Management Systems Engineering, PO Box 6070, West Virginia University, Morgantown, WV 26506-6107, USA. Ashish.Nimbarte@mail.wvu.edu
Abstract:
The primary objective of this study was to quantify the effect of dynamic cart pushing exertions on the biomechanical loading of shoulder and low back. Ten participants performed cart pushing tasks on flat (0°), 5°, and 10° ramped walkways at 20 kg, 30 kg, and 40 kg weight conditions. An optoelectronic motion capturing system configured with two force plates was used for the kinematic and ground reaction force data collection. The experimental data was modeled using AnyBody modeling system to compute three-dimensional peak reaction forces at the shoulder complex (sternoclavicular, acromioclavicular, and glenohumeral) and low back (lumbosacral) joints. The main effect of walkway gradient and cart weight, and gradient by weight interaction on the biomechanical loading of shoulder complex and low back joints was statistically significant (all p < 0.001). At the lumbosacral joint, negligible loading in the mediolateral direction was observed compared to the anterioposterior and compression directions. Among the shoulder complex joints, the peak reaction forces at the acromioclavicular and glenohumeral joints were comparable and much higher than the sternoclavicular joint. Increased shear loading of the lumbosacral joint, distraction loading of glenohumeral joint and inferosuperior loading of the acromioclavicular joint may contribute to the risk of work-related low back and shoulder musculoskeletal disorder with prolonged and repetitive use of carts.
Related Concept Videos
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Normal Strain under Axial Loading
Eccentric Loading
