Related Experiment Video
Updated: May 12, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Gradient chromatography under constant frictional heat: realization and application
Fabrice Gritti1, Georges Guiochon
1Department of Chemistry, University of Tennessee, Knoxville, TN 37996-1600, USA.
Abstract:
A new mode of gradient elution in liquid chromatography is proposed. It is derived from simple theoretical considerations and is particularly suitable for applications to fast, very-high pressure gradients. It is designed to improve the injection-to-injection repeatability of chromatographic runs at either constant flow (cF, cooling case scenario) or constant pressure (cP, heating case scenario). The purpose of this original gradient mode is to minimize the variations of the temperatures and the pressures across and along the column during the gradient time. These variations are caused by the heat generated in the column due to the friction of the eluent percolating the bed. Any temperature fluctuation affects to some extent the precision of the measurements of retention times and bandwidths of eluted compounds. The minimization of this effect was achieved by maintaining constant the frictional heat power (i.e., the product of the flow rate by the column pressure drop) generated during the gradient run, the washing step, and the re-equilibration time. The eluent temperature was recorded at the column outlet. One useful application of gradient chromatography at constant frictional heat (cFH) is illustrated for a 50-100% volume gradient of acetonitrile in water using a 4.6mm × 150 mm column packed with 3.5 μm BEH-C18 particles and operated with an Agilent 1290 Infinity liquid chromatograph. The reproducibility (eleven consecutive injections) of the retention times and peak variances of nine small molecules (RPLC check-out sample mixture) using cF, cP, and cFH gradients were compared for the same amount of heat produced (403 J) during each run time. The RSDs of the retention times and the peak variances for four consecutive injections were systematically below 0.035 and 0.50% in constant frictional heat gradient chromatography, after three initial injections. These RSDs were markedly higher for cF (0.050 and 0.90%) and cP (0.070 and 1.80%) gradients.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
High-Performance Liquid Chromatography: Elution Process
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
High-Performance Liquid Chromatography: Instrumentation

