Related Experiment Video
Updated: May 12, 2026

Laboratory Estimation of Net Trophic Transfer Efficiencies of PCB Congeners to Lake Trout (Salvelinus namaycush) from Its Prey
Published on: August 29, 2014
Plasma polychlorinated biphenyls in residents of 91 PCB-contaminated and 108 non-contaminated dwellings-an exposure
Harald William Meyer1, Marie Frederiksen, Thomas Göen
1Department of Occupational and Environmental Medicine, Bispebjerg University Hospital, Bispebjerg Bakke 23, 2400 Copenhagen NV, Denmark.
Background:
In the1950s-1970s polychlorinated biphenyls (PCBs) were used in several countries as plasticizers in elastic sealants in buildings.
Objective:
The primary objective was to study whether residents of PCB-contaminated dwellings had higher plasma levels of PCBs than their neighbours in non-contaminated dwellings. The secondary objective was to study possible associations between concentrations of PCBs in the indoor air and in the plasma of residents.
Methods:
Stratified cross-sectional study of residents of a housing estate with four sections, of which only one section had PCB-containing sealants. The determination of 27 PCB congeners in plasma was performed among 134 exposed and 139 non-exposed residents. Air measurements were conducted in 104 flats.
Results:
Significant differences in plasma PCBs between exposed versus non-exposed were found for most of the lower chlorinated and many of the higher chlorinated congeners. The median of sum of 27 PCBs was approximately four times higher in exposed compared with non-exposed residents. The elevated PCB concentrations persisted in multivariable analyses controlling for relevant cofactors. We found significant correlations between PCB indoor air concentrations and the PCB concentration in the plasma of the residents for ten of the lower chlorinated congeners.
Conclusion:
Our study confirms that indoor air exposure to PCBs from PCB containing sealants may result in a considerable internal PCBs exposure of the residents. For the first time we were able to demonstrate that the internal exposure to low chlorinated PCBs is significantly associated with the indoor air concentration of these congeners.
More Related Videos
07:08Long-term Behavioral and Reproductive Consequences of Embryonic Exposure to Low-dose Toxicants
Published on: March 6, 2018
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022