Related Experiment Video
Updated: May 12, 2026

Ultrafast Time-resolved Near-IR Stimulated Raman Measurements of Functional π-conjugate Systems
Published on: February 10, 2020
Phase-matching and dilution effects in two-dimensional femtosecond stimulated Raman spectroscopy
Barbara Dunlap1, Kristina C Wilson, David W McCamant
1Department of Chemistry, University of Rochester, 120 Trustee Rd., Rochester, New York 14627, USA.
Abstract:
We present theoretical and experimental data for the attenuation of the cascade signal in two-dimensional femtosecond stimulated Raman spectroscopy (2D-FSRS). In previous studies, the cascade signal, caused by two third-order interactions, was found to overwhelm the desired fifth-order signal that would measure vibrational anharmonic coupling. Theoretically, it is found that changing the phase-matching conditions and sample concentration would attenuate the cascade signal, while only slightly decreasing the fifth-order signal. By increasing the crossing angle between the Raman pump and probe and the impulsive pump and probe, the phase-matching efficiency of the cascade signal is significantly attenuated, while the fifth-order efficiency remains constant. The dilution experiments take advantage of the difference in the concentration dependence for the fifth-order and cascade signal, in which the fifth-order signal is proportional to concentration and the cascade signal is proportional to concentration squared. Experimentally, it is difficult to see a trend in the data due to instability in signal in the phase-matching experiments and lack of signal at low concentrations in the dilution experiments.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse.
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...

