Related Experiment Video
Updated: May 12, 2026

05:21
Computerized Adaptive Testing System of Functional Assessment of Stroke
Published on: January 7, 2019
Development of a computer-adaptive physical function instrument for Social Security Administration disability
Pengsheng Ni1, Christine M McDonough, Alan M Jette
1Department of Health Policy and Management, The Health and Disability Research Institute, School of Public Health, Boston University Medical Campus, Boston, MA, USA. psni@bu.edu
Archives of Physical Medicine and Rehabilitation
|April 13, 2013
Summary
The Social Security Administration-Physical Function (SSA-PF) instrument uses item response theory to create a reliable tool for assessing physical function in disability programs. This new method offers accurate measurement for claimants and the general population.
Area of Science:
- Psychometrics
- Disability Assessment
- Health Measurement
Background:
- The Social Security Administration (SSA) requires robust methods to evaluate physical function for disability claims.
- Existing assessment tools may not adequately capture the nuances of physical function relevant to SSA disability programs.
- Development of a specialized instrument is needed to improve the accuracy and efficiency of disability evaluations.
Purpose of the Study:
- To develop and psychometrically test the SSA-Physical Function (SSA-PF) instrument for assessing physical function in SSA disability programs.
- To create a calibrated item bank using item response theory (IRT) for key physical function domains.
- To develop and evaluate computer-adaptive testing (CAT) versions of the SSA-PF instrument.
Main Methods:
- Cross-sectional data collection from SSA claimants (n=1017) and U.S. general population adults (n=999) via telephone and internet surveys.
- Item response theory (IRT) analyses to develop 5 unidimensional SSA-PF scales (Changing & Maintaining Body Position, Whole Body Mobility, Upper Body Function, Upper Extremity Fine Motor, Wheelchair Mobility) comprising 102 items.
- Computer-adaptive testing (CAT) simulations were used to assess the accuracy, reliability, and precision of the developed instruments.
Main Results:
- IRT analyses successfully yielded 5 distinct SSA-PF scales with 102 items, demonstrating unidimensionality.
- Simulated CAT versions showed high accuracy, with strong correlations to full item bank scores and minimal loss in reliability or precision.
- Claimant scores were generally lower than those of the general population sample, indicating a potential shift in physical function levels.
Conclusions:
- The SSA-PF instrument represents a significant methodological advancement for measuring physical function in adults applying for SSA disability benefits.
- The instrument demonstrates broad content coverage across key physical function domains.
- Initial psychometric evaluations indicate the SSA-PF instrument possesses noteworthy reliability and validity for its intended use.
Keywords:
CATDIFDisability evaluationDisabled personsHealth Status IndicatorsIRTInsurancePROMISPatient-Reported Outcomes Measurement Information SystemPsychometricsQuestionnairesRehabilitationSSASSA-PFSocial Security AdministrationSocial Security Administration Physical FunctionStatistical modelcomputer-adaptive testingdifferential item functioningitem response theory