Magneto-inductive catheter receiver for magnetic resonance imaging
Richard R A Syms1, Ian R Young, Munir M Ahmad
1Department of Electrical and Electronic Engineering, Imperial College London, London, SW7 2AZ, UK. r.syms@imperial.ac.uk
A novel catheter-based radiofrequency (RF) receiver enables internal magnetic resonance imaging (MRI). This device uses a metamaterial waveguide for signal transmission, achieving submillimeter resolution for potential clinical applications.
Area of Science:
- Medical Devices
- Magnetic Resonance Imaging
- Metamaterials
Background:
- Internal magnetic resonance imaging (MRI) requires specialized radiofrequency (RF) receiver technology.
- Existing solutions face challenges in signal transmission and compatibility with clinical workflows.
- Metamaterials offer unique electromagnetic properties for novel device designs.
Purpose of the Study:
- To demonstrate a catheter-based RF receiver for internal MRI.
- To develop a device compatible with existing clinical tools like duodenoscopes and guidewires.
- To achieve high-resolution imaging in internal anatomical regions.
Main Methods:
- Fabrication of a double-sided thin-film circuit wrapped around a hollow catheter.
- Utilized a resonant LC circuit at the catheter tip for signal detection.
- Employed a magneto-inductive waveguide (coupled LC circuits) for signal transmission along the catheter.
- Incorporated figure-of-eight elements for decoupling from external B1 and E fields.
- Coupled the system to a conventional RF system via a demountable inductive transducer.
Main Results:
- Successfully demonstrated decoupling against external B1 and E fields.
- Achieved in vitro (1)H magnetic resonance imaging with submillimeter resolution at 1.5 T using phantoms.
- The device is guidewire-compatible and can pass through a duodenoscope biopsy channel.
Conclusions:
- The developed catheter-based RF receiver is a viable technology for internal MRI.
- The system's design facilitates integration into current clinical practices, particularly for biliary imaging.
- This innovation holds potential for advancing image-guided procedures.
More Related Videos
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
12:24Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse
Published on: June 20, 2014
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...