Related Experiment Video
Updated: May 12, 2026

Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI-TOF) Mass Spectrometry
Published on: June 10, 2018
Ion-to-neutral ratio of 2,5-dihydroxybenzoic acid in matrix-assisted laser desorption/ionization
Ming-Tsang Tsai1, Sheng Lee, I-Chung Lu
1Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, Taiwan.
Rationale:
In most previous studies, the ratios of desorbed ions and neutrals from matrix-assisted laser desorption/ionization (MALDI) were measured outside the common MALDI conditions. In this work, we measured the ratios under common MALDI conditions.
Methods:
Ions were detected using a time-of-flight mass spectrometer in combination with a time-gated ion imaging detector. Mass-resolved desorbed neutral molecules at different angles and velocities were measured using a modified crossed molecular beam apparatus.
Results:
The upper limit of the ion-to-neutral ratio from pure 2,5-dihydroxybenzoic acid (25DHB) is 4 × 10(-9) at laser fluence 40 J/m(2), it increases to 3 × 10(-7) at laser fluence 250 J/m(2). The ratios of matrix from the mixture of 25DHB and analyte remain in the same order of magnitude as pure 25DHB. However, the ratio of analyte depends strongly on the analyte. Values as large as 10(-3)-10(-4) for bradykinin and as small as <10(-8) for glycine were observed at laser fluence ~100 J/m(2).
Conclusion:
The ion-to-neutral ratios of 25DHB matrix measured in this work are much smaller than some of the values reported in previous work using different methods and/or under different MALDI conditions.
More Related Videos
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
07:49Matrix-assisted Laser Desorption/Ionization Time of Flight (MALDI-TOF) Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
MALDI-TOF Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Chemical Ionization (CI) Mass Spectrometry
Polyprotic Acids