Related Experiment Video
Updated: May 12, 2026

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
Balloon-assisted tracking: a must-know technique to overcome difficult anatomy during transradial approach
Tejas Patel1, Sanjay Shah, Samir Pancholy
1Apex Heart Institute, Ahmedabad, India; Department of Cardiology, Sheth V.S. General Hospital and Smt. N.H.L. Municipal Medical College, Ahmedabad, 380 006, India.
Objective:
To examine the use and outcomes of balloon-assisted tracking (BAT) technique for dealing with complexities of arm and chest vasculature during transradial approach (TRA) at a single high volume radial center.
Background:
TRA has been used for coronary angiography and percutaneous coronary interventions (PCI) around the world. Different techniques have been described to address the anatomical issues and tortuosities for successful completion of coronary angiography and PCI. This study describes the use of BAT technique and associated outcomes during real world clinical practice.
Methods:
Subjects comprised 63 patients, (out of total 8,245 patients between January 2011 and December 2012) in whom we encountered significantly complex anatomical course in radial, brachial, or subclavian region, leading to difficult advancement of a diagnostic or a guide catheter despite trying all standard maneuvers. In all of them BAT technique was used and they were retrospectively analyzed for the purpose of this study.
Results:
About 63 (0.76%) of 8,245 patients met the study criteria. Twenty-five (39.7%) patients had very small RA. Twenty-two (34.9%) had severe RA tortuosity. Four (6.3%) had complex RA loops. Six (9.5%) had severe RA spasm and six (9.5%) had severe subclavian tortuosity and/or stenosis. We encountered technical failure in three (4.8%) patients (two had very small RA and one had 360 degree RA loop).
Conclusion:
BAT technique was useful to address the anatomical issues and tortuosities of radial, brachial, and subclavian vasculature during TRA.
More Related Videos
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

