A Rat Model of Orthotopic Liver Transplantation Using a Novel Magnetic Anastomosis Technique for Suprahepatic Vena Cava Reconstruction
Published on: March 19, 2018
Magnetic compression in gastrointestinal and bilioenteric anastomosis: how much force?
Tadhg Lambe1, Mícheál G Ó Ríordáin, Ronan A Cahill
11University College Cork, Cork, Ireland.
Aim:
The concept of compression alimentary anastomosis is well established. Recently, magnetic axial alignment pressures have been encompassed within such device constructs. We quantify the magnetic compression force and pressure required to successfully achieve gastrointestinal and bilioenteric anastomosis by in-depth interrogation of the reported literature.
Methods:
Reports of successful deployment and proof of anastomotic patency on survival were scrutinized to quantify the necessary dimensions and strengths of magnetic devices in (a) gastroenteral anastomosis in live porcine models and (b) bilioenteric anastomosis in the clinical setting. Using a calculatory tool developed for this work (magnetic force determination algorithm, MAGDA), ideal magnetic force and compression pressure were quantified from successful reports with regard to their variance by intermagnet separation.
Results:
Optimized ranges for both compression force and pressure were determined for successful porcine gastroenteral and clinical bilioenteric anastomoses. For gastroenteral anastomoses (porcine investigations), an optimized compression force between 2.55 and 3.57 kg at 2-mm intermagnet separation is recommended. The associated compression pressure should not exceed 60 N/cm(2). Successful bilioenteric anastomoses is best clinically achieved with intermagnet compression of 18 to 31 g and associated pressures between 1 and 3.5 N/mm(2) (at 2-mm intermagnet separation).
Conclusion:
The creation of magnetic compression anastomoses using permanent magnets demonstrates a remarkable resilience to variations in magnetic force and pressure exertion. However, inappropriate selection of compression characteristics and magnet dimensions may incur difficulties. Recommendations of this work and the availability of the free online tool (http://magda.ucc.ie/) may facilitate a factor of robustness in the design and refinement of future devices.
More Related Videos
09:29Fabrication and Implantation of Miniature Dual-element Strain Gages for Measuring In Vivo Gastrointestinal Contractions in Rodents.
Published on: September 18, 2014
09:41Magnet Assisted Composite Manufacturing: A Flexible New Technique for Achieving High Consolidation Pressure in Vacuum Bag/Lay-Up Processes
Published on: May 17, 2018
Related Concept Videos
Magnetic Force Between Two Parallel Currents
The force exerted by the magnetic field due to the first conductor over a finite length of the second conductor is given as the product of the current in the second conductor and the vector product of the length vector along the current element and the field due to the first conductor. According to the...
Magnetic Force On Current-Carrying Wires: Example
Force On A Current Loop In A Magnetic Field
Intestinal Obstruction II: Pathophysiology
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...