Related Experiment Video
Updated: May 12, 2026

Implantation Protocol of the Foldable Capsular Vitreous Body for Complex Vitreoretinal Surgery
Published on: April 14, 2026
[Clinical results after implantation of a new segmental refractive multifocal intraocular lens]
B C Thomas1, G U Auffarth, R Philips
1International Vision Correction Research Centre (IVCRC), Univ.-Augenklinik Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Deutschland.
Background:
The aim of the study was a clinical evaluation of an intraocular lens (IOL) with a segmental multifocal optic design and near addition of + 3.0 D as part of a CE approval study.
Patients And Methods:
In a multicenter study the LENTIS Mplus LS-312 MF IOL (Oculentis) was implanted in 134 eyes of 79 patients with a mean age of 68 ± 12 years. The multifocality is achieved by implementation of a distance part and a segmented near sector. Three months after surgery, uncorrected and best corrected distance visual acuity (UCDVA and BCDVA, respectively), near visual acuity (UCNVA and BCNVA, respectively), contrast vision and patient satisfaction (questionnaire) were evaluated.
Results:
The IOLs were implanted uneventfully either unilaterally or bilaterally and 3 months postoperatively (n = 86 eyes) the following mean visual acuities were obtained (logMAR): UCDVA = 0.05, BCDVA = - 0.01, UCNVA = 0.09 and BCNVA = 0.02. Contrast sensitivity (n = 25 eyes) was within normal limits. Of the 66 questioned patients 10.6% spontaneously reported halos and 3% glare.
Conclusion:
This new innovative multifocal IOL concept showed very good functional results as well as high patient satisfaction.
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...