Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
A new concept for variance analysis of hyphenated chromatographic data avoiding signal warping
Piotr Zerzucha1, Małgorzata Kazura, Dalene de Beer
1Institute of Chemistry, The University of Silesia, Szkolna Street 9, 40-006 Katowice, Poland.
Abstract:
Analysis of variance of chromatographic data is usually performed on the peak table or on entire chromatograms. These two data forms require signal pretreatment. Peak table requires peak detection, their standards and quantification, and the second form of data organization requires warping of the studied chromatograms to eliminate the observed peak shifts, which occurs due to minor variations in chromatographic conditions. In our study, a new form of data representation well suited for chromatographic data originating from multi-channel detection is proposed. It requires neither warping of chromatograms, nor peak detection. Its principles and performance are demonstrated for a real data set (being a part of a larger research project initiated to characterize the infusion of fermented rooibos herbal tea in terms of phenolic composition and antioxidant activity). As the method of choice for the analysis of data variation, the Multiple Analysis of Variance applied to the pairwise data representation was chosen.
More Related Videos
07:502D-HPLC-MS Technology Combined with Molecular Network for the Identification of Components in Tibetan Medicine Aconitum pendulum
Published on: December 8, 2023
08:49Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy
Published on: December 1, 2023
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process