Related Experiment Video
Updated: May 12, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Simultaneous determination of typical substituted and parent polycyclic aromatic hydrocarbons in water and solid
Meng Qiao1, Weixiao Qi, Huijuan Liu
1State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
Abstract:
Polycyclic aromatic hydrocarbons (PAHs) are likely to transform to more mutagenic and carcinogenic substituted polycyclic aromatic hydrocarbons (SPAHs) in the environment. To date, no literature has reported on an analytical method for SPAHs in the natural water environment (encompassing water, suspended particulate and sediment matrix). A robust and routine analytical method was developed for simultaneous detection of 13 typical SPAHs and 16 PAHs in the water environment in this work. The pretreatment and instrument analysis procedure were optimized for effective detection of the 29 targets species. Recovery of each target ranged from 60% to 120%, except for benz[a]anthracene-7,12-dione (BA-7,12-D), which resulted from the transformation of 7-nitrobenz[a]anthracene (7-NBA). The high recovery of BA-7,12-D was relatively stable, so the detection results could be corrected. The method quantification limits ranged from 0.04ng/L to 20.25ng/L for 4L water samples, from 4.12ng/g to 131.66ng/g for 0.1g particulate samples, and from 1.75ng/g to 28.04ng/g for 20g sediment samples. The method was applied to detect the 29 targets pollutants in polluted rivers, receiving wastewater from Beijing and Tianjin in China. Certain SPAH targets including 2-methylnaphthalene, 2,6-dimethylnaphthalene, 1-methylfluoranthene, 3,6-dimethylphenanthrene, 9-fluorenone, anthraquinone, 2-methylanthranquinone and BA-7,12-D were detected in the natural river environment, and all PAH targets were found in rivers.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...

