The combination of infrared and microwave radiation to quantify trace elements in organic samples by ICP OES
A N S Dantas1, W O Matos, S T Gouveia
1Laboratório de Estudos em Química Aplicada (LEQA), Departamento de Química Analítica e Físico-Química, Universidade Federal do Ceará, Campus do Pici, Fortaleza-Ce, Brazil.
Abstract:
Sample-decomposition methods using microwave radiation in closed systems have been commonly used in the analysis of inorganic constituents; however, these methods are limited to small amounts of organic samples. This work proposes the combined use of infrared radiation and microwave radiation (IR-MW) to increase the amount of organic samples digested. The determination of Al, Ca, Cu, Fe, K, Mg, Mn, Na, P and Zn in human-feed samples was accomplished by ICP OES. The results were in agreement with those obtained from conventional decomposition by microwave radiation (closed system). The results obtained using the proposed IR-MW system for standard reference material (whole milk powder, NIST 8435) were also compared. Agreements of 85-100% were obtained for Al, Ca, Cu, Fe, K, Mg, Na, P and Zn in the standard reference material. The IR-MW system is simple to implement and cheap because it uses commercially available infrared lamps and allows the use of infrared radiation in the microwave-digestion vessel. Additionally, it is possible to reach better precision in the analysis of the human-feed samples using the IR-MW system. The proposed method also allows total digestion of large sample amounts or samples rich in organic compounds can also be performed in the IR-MW system using small volumes of nitric acid.
More Related Videos
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry (CE-ICP-MS) for Quantification of Iron Redox Species (Fe(II), Fe(III))
Published on: May 4, 2020
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab