Updated: May 12, 2026

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
07:10

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy

Published on: June 18, 2020

Transjugular liver biopsy: tips and tricks.

Manisha Jana1, Shivanand Gamanagatti

  • 1Department of Radiodiagnosis, All India Institute of Medical Sciences, New Delhi, India.

Tropical Gastroenterology : Official Journal of the Digestive Diseases Foundation
|April 23, 2013
PubMed
Summary

Transjugular liver biopsy (TJLB) offers a safer alternative to percutaneous liver biopsy for specific patients. This review details TJLB instrumentation, techniques, complications, and troubleshooting for improved procedural success.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Quantitative MR biomarkers in identifying steatohepatitis and fibrosis associated with metabolic dysfunction associated liver disease-a single center cross-sectional study.

Abdominal radiology (New York)·2026
Same author

A phase II study of cabozantinib in metastatic or unresectable refractory gastrointestinal stromal tumour(GIST): a single-centre study from India.

BMC cancer·2026
Same author

Imaging in Juvenile Idiopathic Arthritis: A Comprehensive Review.

The Indian journal of radiology & imaging·2026
Same author

Bevacizumab added to conventional induction chemotherapy for children with high risk neuroblastoma (BRAVEN trial).

Discover oncology·2026
Same author

Implementation of pediatric and fetal postmortem imaging into clinical practice: a multi-society statement from the ESPR, SPR, SLARP, AOSPR, WFPI, and IAFR.

Pediatric radiology·2026
Same author

The 'Madura Hand'.

QJM : monthly journal of the Association of Physicians·2026

Area of Science:

  • Interventional Radiology
  • Hepatology
  • Gastroenterology

Background:

  • Percutaneous liver biopsy carries risks, particularly in patients with ascites or bleeding issues.
  • Transjugular liver biopsy (TJLB) presents a viable alternative in challenging patient populations.
  • Optimizing TJLB requires understanding specific instrumentation and techniques.

Purpose of the Study:

  • To provide a comprehensive overview of the transjugular liver biopsy (TJLB) procedure.
  • To detail the necessary instrumentation for successful TJLB.
  • To discuss common complications and troubleshooting strategies for TJLB.

Main Methods:

  • Review of instrumentation for transjugular liver biopsy.
  • Description of the technical aspects of performing TJLB.
  • Analysis of common complications and their management.

Main Results:

  • TJLB is a relatively safer method compared to percutaneous biopsy in select patients.
  • Instrumentation includes specialized catheters, guidewires, and biopsy needles.
  • Common complications include bleeding and arrhythmia; troubleshooting involves careful technique and device selection.

Conclusions:

  • Transjugular liver biopsy (TJLB) is an essential procedure for patients with contraindications to percutaneous biopsy.
  • Mastery of TJLB instrumentation and technique is crucial for minimizing complications.
  • Effective troubleshooting ensures patient safety and diagnostic yield in TJLB.

More Related Videos

Method of Direct Segmental Intra-hepatic Delivery Using a Rat Liver Hilar Clamp Model
09:22

Method of Direct Segmental Intra-hepatic Delivery Using a Rat Liver Hilar Clamp Model

Published on: April 2, 2017

Successful Orthotopic Liver Transplantation in Mice Utilizing Microcomputed Tomography Angiography
09:23

Successful Orthotopic Liver Transplantation in Mice Utilizing Microcomputed Tomography Angiography

Published on: September 22, 2023

Related Experiment Videos

Last Updated: May 12, 2026

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
07:10

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy

Published on: June 18, 2020

Method of Direct Segmental Intra-hepatic Delivery Using a Rat Liver Hilar Clamp Model
09:22

Method of Direct Segmental Intra-hepatic Delivery Using a Rat Liver Hilar Clamp Model

Published on: April 2, 2017

Successful Orthotopic Liver Transplantation in Mice Utilizing Microcomputed Tomography Angiography
09:23

Successful Orthotopic Liver Transplantation in Mice Utilizing Microcomputed Tomography Angiography

Published on: September 22, 2023