Ionic liquid coated magnetic nanoparticles for the gas chromatography/mass spectrometric determination of polycyclic aromatic hydrocarbons in waters
Related Experiment Video
Updated: May 12, 2026

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Francisco Galán-Cano1, María del Carmen Alcudia-León, Rafael Lucena
1Department of Analytical Chemistry, Institute of Fine Chemistry and Nanochemistry, Marie Curie Building, Campus de Rabanales, University of Córdoba, 14071 Córdoba, Spain.
Abstract:
In this paper, ionic liquid coated magnetic nanoparticles (IL-MNPs) have been prepared by covalent immobilization. The as-synthesized MNPs have been successfully used as sorbent for the extraction of polycyclic aromatic hydrocarbons (PAHs) from water samples, the analytes being finally determined by gas chromatography/mass spectrometry. The influence of several experimental variables (including the ionic strength, amount of MNPs, sample volume, agitation time and desorption solvent) has been considered in depth in the optimization process. The developed method, which has been analytically characterized under its optimal operation conditions, allows the detection of the analytes in the samples with method detection limits in the range from 0.04μgL(-1) (fluoranthene) to 1.11μgL(-1) (indeno(1,2,3-cd)pyrene). The repeatability of the method, expressed as relative standard deviation (RSD, n=7), varies between 4.0% (benzo[b]fluoranthene) and 8.9% (acenaphthene), while the enrichment factors are in the range from 49 (naphthalene) to 158 (fluoranthene). The proposed procedure has been applied for the determination of thirteen PAHs in water samples (tap, river, well and reservoir ones) with recoveries in the range from 75 to 102%.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...