Related Experiment Video
Updated: May 12, 2026

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Assessment of needle guidance devices for their potential to reduce fluoroscopy time and operator hand dose during
Maarten W Kroes1, Wendy M H Busser, Jurgen J Fütterer
1Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands. m.kroes@rad.umcn.nl
Purpose:
To assess whether the use of needle guidance devices can reduce fluoroscopy time and operator hand dose during cone-beam computed tomography-guided needle interventions.
Materials And Methods:
The freehand technique was compared with techniques employing two distinct needle holders and a ceiling-mounted laser guidance technique. Laser guidance was used either alone or in combination with needle holders. Four interventional radiologists were instructed to reach predetermined targets in an abdominal phantom using these techniques. Each operator used all six techniques three times. Fluoroscopy time, procedure time, operator hand dose, and needle tip deviation were obtained for all simulated needle interventions. All data are presented as median (ranges).
Results:
All procedures were successfully completed within 2-4 minutes, resulting in a deviation from target of 0.8 mm (0-4.7). In freehand procedures, the fluoroscopy time to reach the target was 50 seconds (31-98 s). Laser guidance, used alone or in combination with needle holders, reduced fluoroscopy time to 31 seconds (14-68 s) (P<.02). The operator hand dose in freehand procedures was 275 μSv (20-603 μSv). Laser guidance alone or in combination with needle holders resulted in a reduction of the hand dose to<36 μSv (5-82 μSv) per procedure (P<.001). There were no statistically significant effects on hand dose levels or fluoroscopy time when the needle holders were employed alone.
Conclusions:
Compared with the freehand technique, all three tested needle guidance devices performed with equivalent efficiency in terms of accuracy and procedure time. Only the addition of laser guidance was found to reduce both fluoroscopy time and operator hand dose.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...