Related Experiment Video
Updated: May 12, 2026

Collection and Extraction of Occupational Air Samples for Analysis of Fungal DNA
Published on: May 2, 2018
Toxicity screening of materials from buildings with fungal indoor air quality problems (Stachybotrys chartarum)
1Mount Sinai School of Medicine, Dep. Community Medicine, Eastern New York Occupational and Environmental Health Center, Albany, N.Y., johanni2@knick.net.
Abstract:
Samples of building materials visibly contaminated with moisture-related fungi (drywall, fiberglass, wallpaper, wood) were tested with indirect (FFL) and direct (MTT) cytotoxicity screening tests that are particularly sensitive toStachybotrys chartarum toxins. In addition, microscopic, chemical, immunochemical (Roridin A enzyme immunoassay) and mycological culture analyses were performed. In all cases in which building occupants had reported verifiable skin, mucous membrane, respiratory, central nervous system or neuropsychological abnormalities, cytotoxicity was identified. Results of a cytotoxicity screening test of field samples, such as the direct MTT test method, will give investigators of health problems related to indoor air quality problems important toxicity information.
Related Concept Videos
Biodeterioration
Toxic Reactions: Overview
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...