Related Experiment Video
Updated: May 12, 2026

How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
A prospective assessment of renal oxygenation in children undergoing laparoscopy using near-infrared spectroscopy
Chris Westgarth-Taylor1, Leonnie de Lijster, Guido van Bogerijen
1Department of Paediatric Surgery, University of Cape Town and Red Cross War Memorial Children's Hospital, Rondebosch, 7700, Cape Town, South Africa, drcwtaylor@gmail.com.
Background:
This study was designed to determine whether a decrease in renal oxygenation occurs during CO2 pneumoperitoneum in children with normal renal function undergoing laparoscopy.
Methods:
Near infrared spectroscopy (NIRS) probes were applied to both the lateral flank (T10-L2) and lateral cerebral area of all patients with normal renal function undergoing a laparoscopic procedure. Information was recorded in 5-s intervals for 15-min before, during, and for 15-min after pneumoperitoneum insufflation and desufflation. Simultaneously, additional hemodynamic parameters (arterial saturation, mean arterial pressure, end tidal CO2, and urine output) were recorded every 5-min. Pneumoperitoneum pressures used were: 0-1 month old, <6 mmHg; 2-12 months old, <8 mmHg; 1-2 years old, <10 mmHg, and 2-8 years old, <12 mmHg. The lowest possible pressure was used to obtain adequate vision.
Results:
Twenty-nine patients were enrolled in the study. Renal regional oxygen saturation (rSO2) did not decrease significantly between baseline (preinsufflation), insufflation, and desufflation of the pneumoperitoneum (p = 0.343). Meta-analysis of this data demonstrated a pooled weighted difference of -1.4 (-3.5 to 0.54), confirming no significant change. A significant increase in cerebral rSO2 occurred during the insufflation period of the CO2 pneumoperitoneum (p = 0.001). Heart rate (F = 11.05; p < 0.001) and mean arterial pressure (MAP) (F = 19.2; p < 0.001) also increased significantly during the laparoscopy. No significant correlation was identified between fluid input and urine output during the laparoscopy (r = 0.012; p = 0.953).
Conclusions:
Renal hypoxia does not occur during laparoscopic surgery in children if the minimum age-appropriate intra-abdominal pressures are used. Alternative causes must account for the oliguria and anuria demonstrated in children undergoing laparoscopy.
More Related Videos
04:36Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024