Related Experiment Video
Updated: May 12, 2026

A Gusseted Thermogradient Table to Control Soil Temperatures for Evaluating Plant Growth and Monitoring Soil Processes
Published on: October 22, 2016
Realization and potential advantages of gradient separations performed under steady state temperature regime
Fabrice Gritti1, Georges Guiochon
1Department of Chemistry, University of Tennessee, Knoxville, TN 37996-1600, USA.
Abstract:
This paper describes a new method designed to perform gradient separations while keeping constant the distribution of temperature throughout the column during the three phases of a gradient run (the ramp up of the strong eluent concentration, the column wash, and the re-equilibration steps) in high pressure liquid chromatography (vHPLC). The method is based on the solution of the integrated heat balance equation along the column knowing the variations of the eluent specific heat, its thermal expansion coefficient, and its viscosity with the concentration of the strong eluent. This new method is called gradient under constant wall heat (cWH). Its value is demonstrated by the stability of the eluent temperature at the column outlet during a series of consecutive gradient runs. The potential advantages of cWH gradients over classical gradients execution mode at constant flow rate (cF) are illustrated in the example of two such gradients run in the same time. They include (1) a diminution by a factor 8 of the largest temperature variation during the sequence of injections (0.4°C versus 3.2°C); (2) a reduction of the baseline noise by a factor two (0.05mAU versus 0.10mAU); and (3) the achievement of an excellent injection-to-injection repeatability of the vHPLC system used to measure the first (average RSDs, 0.04%) and the second central (average RSDs≃0.75%) moments of the peaks of an eight-compounds mix, baseline separated, from the first to the last injection.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Principles Of Column Chromatography
Overview Of Cell Separation And Isolation
High-Performance Liquid Chromatography: Elution Process
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Centrifugation

