Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

From Transseptal Puncture to Mitral Commissurotomy: A Zero-Wire-Exchange Approach Using Inoue Balloon.

JACC. Case reports·2026
Same author

A photoexcited triplet state germylene with a half-life of hours at room temperature.

Nature chemistry·2026
Same author

Tachycardia-Mediated Cardiomyopathy from Concealed Left-Sided AVRT with Complete Recovery Post-Ablation.

Oxford medical case reports·2026
Same author

Synergistic biocontrol of Parthenium hysterophorus: the role of Curvularia specifera and Zygogramma bicolorata.

Archives of microbiology·2026
Same author

Comprehending the impact of hydro-meteorological droughts on ecosystem vulnerability and resilience across the Indus River Basin in Pakistan.

Journal of environmental management·2026
Same author

Management of Coronary Artery Perforations: A Stepwise, Case-Based Review From a High-Volume Center.

JACC. Case reports·2026

Related Experiment Video

Updated: May 12, 2026

Highly Resolved Intravital Striped-illumination Microscopy of Germinal Centers
10:07

Highly Resolved Intravital Striped-illumination Microscopy of Germinal Centers

Published on: April 9, 2014

Super resolution imaging achieved by using on-axis interferometry based on a Spatial Light Modulator.

Anwar Hussain1, J L Martínez, A Lizana

  • 1Department of Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Nilore 45650, Islamabad, Pakistan.

Optics Express
|April 24, 2013
PubMed
Summary
This summary is machine-generated.

This study introduces a novel interferometry method using a Spatial Light Modulator (SLM) to surpass diffraction limits. The technique enables super-resolution imaging by synthesizing a larger aperture from multiple illuminated beams.

More Related Videos

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
08:39

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator

Published on: January 28, 2019

Related Experiment Videos

Last Updated: May 12, 2026

Highly Resolved Intravital Striped-illumination Microscopy of Germinal Centers
10:07

Highly Resolved Intravital Striped-illumination Microscopy of Germinal Centers

Published on: April 9, 2014

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
08:39

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator

Published on: January 28, 2019

Area of Science:

  • Optical imaging
  • Super-resolution microscopy
  • Interferometry

Background:

  • Diffraction limits restrict optical resolution.
  • Overcoming these barriers is crucial for detailed imaging.
  • Existing methods often involve complex setups or sample manipulation.

Purpose of the Study:

  • To propose a new interferometry-based method for achieving resolution beyond the diffraction limit.
  • To utilize a Spatial Light Modulator (SLM) for beam manipulation and phase control.
  • To demonstrate a practical approach for super-resolution imaging.

Main Methods:

  • Illuminating an object with multiple tilted beams generated by an SLM.
  • Assigning constant phases to each tilted beam via the SLM.
  • Forming on-axis interferograms for each phase set.
  • Calculating a synthetic aperture by selecting appropriate phases.
  • Combining shifted Fourier spectra of interferograms for inverse Fourier transform.

Main Results:

  • Successful generation of an interferometry scheme with controlled beam tilting and phase.
  • Demonstration of synthetic aperture calculation through post-processing of interferograms.
  • Obtaining a high-resolution image via inverse Fourier transform of the synthesized spectrum.

Conclusions:

  • The proposed method effectively overcomes the diffraction barrier.
  • SLM-based beam and phase control is key to synthetic aperture generation.
  • This technique offers a viable route to advanced super-resolution imaging.