Related Experiment Video
Updated: May 12, 2026

Diagnosis of Neoplasia in Barrett’s Esophagus using Vital-dye Enhanced Fluorescence Imaging
Published on: May 11, 2014
A comparison of white light laryngostroboscopy versus autofluorescence endoscopy in the evaluation of vocal fold
Philipp P Caffier1, Bernd Schmidt, Manfred Gross
1Department of Audiology and Phoniatrics, Charité - University Medicine Berlin, Berlin, Germany. philipp.caffier@charite.de
Objectives/Hypothesis:
To prove the diagnostic value of autofluorescence endoscopy (AFE) and white light laryngostroboscopy (WLS) versus the gold standard microlaryngoscopy with histopathological examination in differential diagnostics of laryngeal lesions for experienced phoniatricians and laryngologists, using the PENTAX SAFE-3000 system.
Study Design:
Exploratory cohort study.
Methods:
High-resolution rigid WLS was executed in 32 consecutive patients with initial manifestation of benign, precancerous, and malignant vocal fold lesions. Fiberoptic blue light AFE (SAFE-3000; λ = 408 nm) was subsequently performed by an experienced endoscopist in a blinded study setting. Findings were rated based on objective WLS and AFE parameters (e.g., phonatory vibration, mucosal wave propagation, and loss of autofluorescence). The clinically assumed WLS and AFE diagnoses were compared with the final histopathology of biopsied material taken during microlaryngoscopy.
Results:
In reference to histopathological diagnosis, WLS achieved a higher sensitivity (100% vs. 94%), specificity (94% vs. 69%), and accuracy (97% vs. 81%) than AFE diagnostics. The concordance between both endoscopic techniques was 87.5% (28/32 patients); additional AFE benefits were not detectable. Significant loss of autofluorescence was observed in malignant findings clinically clearly diagnosed by WLS, but also in chronic inflammation, severe dysplasia, granulomas, vascular polyps, and glottal papillomatosis.
Conclusions:
The evaluation of vocal fold pathology by the clinically experienced examiner precisely applying WLS appears to be more reliable than diagnostics of mucosal tissue changes by means of AFE via the SAFE-3000 system as a relatively nonspecific method. Microlaryngoscopy with histopathological examination and phonomicrosurgical excision of pathologic changes remains the gold standard.
More Related Videos
07:45Minimally Invasive Murine Laryngoscopy for Close-Up Imaging of Laryngeal Motion During Breathing and Swallowing
Published on: December 1, 2023
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to: