Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Automated Microbial Diagnostics01:24

Automated Microbial Diagnostics

Automated diagnostic analyzers have transformed clinical microbiology by providing rapid and reliable methods for pathogen identification and antibiotic susceptibility testing. Among these systems, the Vitek 2 is widely used because it automates the traditionally labor-intensive processes of microbial identification (ID) and antibiotic susceptibility testing (AST), delivering standardized and timely results that are essential for effective patient care.Microbial Identification with ID CardsThe...
Microbial Biosensors01:17

Microbial Biosensors

Microbial biosensors are analytical devices that utilize living microbes to detect specific substances through measurable signals. These devices consist of two main components: biosensing organisms and signal-transducing elements. Biosensing organisms, such as Escherichia coli or Saccharomyces cerevisiae, are typically housed in multiwell plates connected to transducers, enabling rapid, real-time detection of target analytes.Signal Generation MechanismWhen a target analyte—such as...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Effective musical training protocols for the rehabilitation of children with cochlear implants: A systematic review.

International journal of pediatric otorhinolaryngology·2026
Same author

Genetic diversity and virulence gene profiling of Vibrio harveyi in a vibriosis-affected European seabass (Dicentrarchus labrax) aquaculture tank.

Marine pollution bulletin·2025
Same author

H<sub>2</sub> inhalation therapy in patients with moderate COVID-19 (H<sub>2</sub>COVID): a prospective ascending-dose phase I clinical trial.

Antimicrobial agents and chemotherapy·2024
Same author

Predicting emotion perception abilities for cochlear implant users.

International journal of audiology·2022
Same author

Solubility and spinnability of cellulose-lignin blends in aqueous NMMO.

Carbohydrate polymers·2020
Same author

Temporal decoding of vocal and musical emotions: Same code, different timecourse?

Brain research·2020
Same journal

AI-driven photophysics-aware design of fluorescent probes with applications in α-synuclein biosensing and inhibitor screening.

Biosensors & bioelectronics·2026
Same journal

Three-dimensional helical integration of high-density linear microelectrode arrays and their cross-tissue applications.

Biosensors & bioelectronics·2026
Same journal

Integration of electrochemical sensors in organ-on-a-chip microfluidic platforms: Advances and perspectives.

Biosensors & bioelectronics·2026
Same journal

DNN-PURE: A deep neural network approach to paper-based urea sensing.

Biosensors & bioelectronics·2026
Same journal

Rationally architected MOF-derived Co<sub>3</sub>O<sub>4</sub>@NiMn-LDH hollow heterostructure-based sensor array empowering sensitive detection and discrimination of neurological biomarkers.

Biosensors & bioelectronics·2026
Same journal

Four-in-one multifunctional CoCu-NC@AuPt nanozyme integrated M13 phage-displayed nanobody based multimodal lateral flow immunoassay for bovine lactoferrin detection.

Biosensors & bioelectronics·2026
See all related articles

Related Experiment Video

Updated: May 12, 2026

Point-of-care CRISPR-based Diagnostics with Premixed and Freeze-dried Reagents
10:16

Point-of-care CRISPR-based Diagnostics with Premixed and Freeze-dried Reagents

Published on: August 16, 2024

A novel handheld fluorescent microarray reader for point-of-care diagnostic.

P Kozma1, A Lehmann, K Wunderlich

  • 1Fraunhofer Institute for Biomedical Engineering (IBMT), Am Mühlenberg 13, 14476 Potsdam-Golm, Germany. peter.kozma@ibmt.fraunhofer.de

Biosensors & Bioelectronics
|April 25, 2013
PubMed
Summary
This summary is machine-generated.

A new handheld optical sensor, portMD-113, quantifies fluorescent microarrays. It offers comparable detection limits to commercial readers but is compact, low-cost, and battery-powered for point-of-care diagnostics.

More Related Videos

Open-Source Miniature Fluorimeter to Monitor Real-Time Isothermal Nucleic Acid Amplification Reactions in Resource-Limited Settings
09:36

Open-Source Miniature Fluorimeter to Monitor Real-Time Isothermal Nucleic Acid Amplification Reactions in Resource-Limited Settings

Published on: February 3, 2021

Highly Sensitive and Rapid Fluorescence Detection with a Portable FRET Analyzer
08:27

Highly Sensitive and Rapid Fluorescence Detection with a Portable FRET Analyzer

Published on: October 1, 2016

Related Experiment Videos

Last Updated: May 12, 2026

Point-of-care CRISPR-based Diagnostics with Premixed and Freeze-dried Reagents
10:16

Point-of-care CRISPR-based Diagnostics with Premixed and Freeze-dried Reagents

Published on: August 16, 2024

Open-Source Miniature Fluorimeter to Monitor Real-Time Isothermal Nucleic Acid Amplification Reactions in Resource-Limited Settings
09:36

Open-Source Miniature Fluorimeter to Monitor Real-Time Isothermal Nucleic Acid Amplification Reactions in Resource-Limited Settings

Published on: February 3, 2021

Highly Sensitive and Rapid Fluorescence Detection with a Portable FRET Analyzer
08:27

Highly Sensitive and Rapid Fluorescence Detection with a Portable FRET Analyzer

Published on: October 1, 2016

Area of Science:

  • Biomedical Engineering
  • Optical Sensing Technology
  • Microarray Analysis

Background:

  • Fluorescent microarrays are crucial for biological complex quantification.
  • Existing microarray readers are often bulky, expensive, and energy-intensive.
  • There is a need for portable, cost-effective microarray quantification solutions.

Purpose of the Study:

  • To develop a novel handheld optical sensor for fluorescent microarray quantification.
  • To demonstrate the sensor's performance and advantages over existing technologies.
  • To explore its potential for point-of-care medical applications.

Main Methods:

  • Development of the portMD-113 handheld optical sensor.
  • Utilizing a planar waveguide and evanescent field for fluorescent excitation.
  • Employing a pinhole array, microlens array, interference filter, and detector array for signal detection.

Main Results:

  • The portMD-113 achieves detection limits comparable to commercial laser scanners.
  • The device is compact, lightweight, and low-cost, featuring no moving parts.
  • It can be powered by a battery or personal computer, enabling portability.

Conclusions:

  • The portMD-113 offers a cost-effective and portable solution for fluorescent microarray quantification.
  • Its design advantages make it suitable for point-of-care medical diagnostics.