Related Experiment Video
Updated: May 12, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
The gender-paradox among patients with implantable cardioverter-defibrillators: a propensity-matched study
Sanjeev P Bhavnani1, Vamsimohan Pavuluri, Craig I Coleman
1Division of Cardiology, Section of Heart Rhythm Management, and the Evidence Based Practice Center, Hartford Hospital, Hartford, Connecticut, USA.
Background:
Several meta-analyses of the implantable cardioverter-defibrillator (ICD) clinical trials have demonstrated that while men derived a mortality reduction with prophylactic ICD implantation, women did not. These trials also observed that women receive less appropriate ICD shock therapy compared to men. We aimed to investigate this "gender-paradox" among a heterogeneous community cohort of patients receiving ICDs.
Methods:
We identified 1,445 consecutive patients undergoing ICD implantation from 1997 to 2007. The study population consisted of 582 patients, of whom 291 were women who could be propensity matched to 291 men, based on age, ejection fraction, implantation indication (primary or secondary), etiology of cardiomyopathy (ischemic or nonischemic), and the presence of a cardiac resynchronization therapy-defibrillator (CRT-D) device. The impact of gender difference on the probability of death and appropriate ICD shocks for ventricular arrhythmias was calculated using multivariable Cox proportional hazards analyses.
Results:
During a mean follow-up of 909 ± 901 days, compared to men, women demonstrated a similar risk of death (25% vs 25%, adjusted hazard ratio [AHR] 1.05 [95% confidence interval (CI) 0.81-1.35], P = 0.74). In contrast, women demonstrated a decreased probability of appropriate ICD-shock therapy (14% vs 19%, AHR 0.80 [95% CI 0.59-0.88], P = 0.03) compared to men, and among cohorts with a nonischemic cardiomyopathy (10% vs 20%, P < 0.001) and CRT-D devices (7% vs 19%, P = 0.01).
Conclusion:
Among a community cohort with ICDs, women have a similar mortality compared to men while experiencing less appropriate ICD therapy. These results support the findings of a lower arrhythmic mortality among women.
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Acute Coronary Syndrome III: Diagnostic Studies