Concept and Implementation of a Single Source Information System in Nuclear Medicine for Myocardial Scintigraphy
Objective:
Data for clinical documentation and medical research are usually managed in separate systems. We developed, implemented and assessed a documentation system for myocardial scintigraphy (SPECT/CT-data) in order to integrate clinical and research documentation. This paper presents concept, implementation and evaluation of this single source system including methods to improve data quality by plausibility checks.
Methods:
We analyzed the documentation process for myocardial scintigraphy, especially for collecting medical history, symptoms and medication as well as stress and rest injection protocols. Corresponding electronic forms were implemented in our hospital information system (HIS) including plausibility checks to support correctness and completeness of data entry. Research data can be extracted from routine data by dedicated HIS reports.
Results:
A single source system based on HIS-electronic documentation merges clinical and scientific documentation and thus avoids multiple documentation. Within nine months 495 patients were documented with our system by 8 physicians and 6 radiographers (466 medical history protocols, 466 stress and 414 rest injection protocols). Documentation consists of 295 attributes, three quarters are conditional items. Data quality improved substantially compared to previous paper-based documentation.
Conclusion:
A single source system to collect routine and research data for myocardial scintigraphy is feasible in a real-world setting and can generate high-quality data through online plausibility checks.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...