Related Experiment Video
Updated: May 12, 2026

Assessment and Evaluation of the High Risk Neonate: The NICU Network Neurobehavioral Scale
Published on: August 25, 2014
Effect of a laboratory result pager on provider behavior in a neonatal intensive care unit
L Samal1, Ta Stavroudis, Re Miller
1Division of General Internal Medicine and Primary Care, Brighman and Women's Hospital.
Background:
A computerized laboratory result paging system (LRPS) that alerts providers about abnormal results ("push") may improve upon active laboratory result review ("pull"). However, implementing such a system in the intensive care setting may be hindered by low signal-to-noise ratio, which may lead to alert fatigue.
Objective:
To evaluate the impact of an LRPS in a Neonatal Intensive Care Unit.
Methods:
Utilizing paper chart review, we tallied provider orders following an abnormal laboratory result before and after implementation of an LRPS. Orders were compared with a predefined set of appropriate orders for such an abnormal result. The likelihood of a provider response in the post-implementation period as compared to the pre-implementation period was analyzed using logistic regression. The provider responses were analyzed using logistic regression to control for potential confounders.
Results:
The likelihood of a provider response to an abnormal laboratory result did not change significantly after implementation of an LRPS. (Odds Ratio 0.90, 95% CI 0.63-1.30, p-value 0.58) However, when providers did respond to an alert, the type of response was different. The proportion of repeat laboratory tests increased. (26/378 vs. 7/278, p-value = 0.02).
Conclusion:
Although the laboratory result pager altered healthcare provider behavior in the Neonatal Intensive Care Unit, it did not increase the overall likelihood of provider response.