Does enhanced CT influence the biological GTV measurement on FDG-PET images?
Pierre Vera1, Romain Modzelewski, Sebastien Hapdey
1Department of Nuclear Medicine, Henri Becquerel Cancer Center and Rouen University Hospital, & QuantIF - LITIS [UPRES EA (Equipe d'Accueil) 4108], Faculty of Medicine, University of Rouen, France. pierre.vera@chb.unicancer.fr
Objectives:
To test the influence of media injection in PET/CT on the functional or gross tumour volume measurement.
Patients And Methods:
Thirty-three patients (56 ± 19 years) with non-Hodgkin's lymphoma (n=22) or Hodgkin's disease (n=11) were prospectively studied at staging. PET/CTs were performed 60 min after injection of FDG. Iopamiron 300 (Iopamidol, 1.5cc/kg) was injected immediately after, followed 50s later by a second craniocaudal CT (CT+). PET images were successively reconstructed using the unenhanced CT (PET-) and the CT+ (PET+) for attenuation correction using iterative reconstruction (4 iterations, 8 subsets, 5mm post-filtering). The SUVmax, SUVmean, SUVpeak and functional tumoural volume were measured in tumoural lymphadenopathies or malignant tissues (n=56 VOIs) using 5 3D-thresholding methods on PET- and PET+ images: absolute SUV value of 2.5; 40% of SUVmax, and 3 adaptative thresholding methods (Vauclin, Black and Schaefer methods).
Results:
The SUVmean and the volume measurement were significantly different (p<0.001) for the five segmentation methods for PET- (p<0.001) and PET+ (p<0.001). The SUVmax, SUVmean and SUVpeak increased significantly in PET+ compared to PET- (2-5%). The SUVpeak was not significantly different for the five segmentation methods. The functional volume measurements were significantly different between PET- and PET+ only for the 2.5 segmentation method (+3%; p=0.001), but not for the 40%, Vauclin, Black and Schaefer methods.
Conclusion:
The functional volume could be measured in PET/CT when CT was performed with enhanced media. Caution should be taken when using the volume delineation method. Volume delineation methods using absolute threshold may artefactually increase the functional volume when enhanced CT is used for attenuation correction. The delineation volume using the relative or adaptative method should be preferred when contrast media are used for PET/CT.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)