Related Experiment Video
Updated: May 11, 2026

Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
Poly(ethylene glycol)-poly(ε-caprolactone) iodinated nanocapsules as contrast agents for X-ray imaging
François Hallouard1, Stéphanie Briançon, Nicolas Anton
1Université Lyon 1, Laboratoire d'Automatique et de Génie dEs Procédés, Equipe de Génie Pharmacotechnique UMR 5007, CNRS, CPE, 43 bd du 11, 69100 Villeurbanne, France. hallouard@lagep.univ-lyon1.fr
Purpose:
Synthesis and formulation of iodinated PCL-mPEG nanocapsules as new original blood pool contrast agents for computed tomography.
Methods:
PCL-mPEG was synthesized and formulated following the emulsion-solvent diffusion process, in the form of iodinated nanocapsules. Physico-chemical characterization of such nano-materials was performed by DLS and transmission electron microscopy. A stability study of the nanocapsules suspension was followed-up to 3 month. Blood biocompatibility was performed. Finally, the nanocapsules suspension radiopacity was evaluated in vitro then in vivo in mice as micro-CT contrast agent.
Results:
In this study, the iodine concentration in nanocapsules suspension was about 70 mgI/mL. Besides, these nanocarriers appeared non-toxic, and stable in suspension. In vivo, i.v. administration of 10 μL/g of mouse body weight of theses nano-particles induced a vascular contrast enhancement of 168 HU and a half-life in blood of 4.2 +/- 0.5 h. Elimination route of these particles appears mainly performed by the liver, without sequestration in spleen and lymph nodes confirming their stealth properties.
Conclusions:
This study proposes the first example of iodinated biodegradable polymeric blood pool contrast agent, able to induce an exploitable contrast enhancement. The main advantage of polymeric system compared to lipid ones, lies in their stability and handling, e.g. towards drying for storage.
More Related Videos
07:26Synthesis of 68Ga Core-doped Iron Oxide Nanoparticles for Dual Positron Emission Tomography /(T1)Magnetic Resonance Imaging
Published on: November 20, 2018
11:27Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...