Related Experiment Video
Updated: May 11, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Stent graft-induced new entry tear after endoluminal grafting for aortic dissection repaired with open interposition
Wadi Gomero-Cure1, Robert C Lowery, Sean O'Donnell
1Department of Vascular Surgery, Washington Hospital Center, Washington, DC.
Abstract:
Thoracic endovascular aortic repair is a successful treatment strategy for type B aortic dissections, with low morbidity and mortality compared with the gold standard of open repair. Questions still remain regarding its long-term durability and complication rate. There is a growing awareness of new entry tears induced by the stent graft, a potentially lethal complication. We report the case of a 74-year-old woman with a complicated retrograde type A aortic dissection treated with endovascular stent graft coverage. She required open surgical conversion after she developed a symptomatic, new entry tear induced by the stent graft.