ValiDichro: a website for validating and quality control of protein circular dichroism spectra

Benjamin Woollett1, Lee Whitmore, Robert W Janes

  • 1Institute of Structural and Molecular Biology, Birkbeck College, University of London, London WC1E 7HX, UK.

Nucleic Acids Research
|April 30, 2013
PubMed
Abstract

Related Concept Videos

Protein Folding Quality Check in the RER01:29

Protein Folding Quality Check in the RER

ER is the primary site for the maturation and folding of soluble and transmembrane secretory proteins. The calnexin cycle is a specific chaperone system that folds and assesses the confirmation of N-glycosylated proteins before they can exit the ER lumen. The primary players of this quality check pipeline are the lectins, ER-resident chaperones, and a glucosyl transferase enzyme. In case the calnexin system in the lumen fails to salvage a misfolded protein, it is transported to the cytoplasm...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
UV–Vis Spectroscopy: Woodward–Fieser Rules01:29

UV–Vis Spectroscopy: Woodward–Fieser Rules

UV–Visible absorption spectra of conjugated dienes arise from the lowest energy π → π* transitions. The light-absorbing part of the molecule is called the chromophore, and the substituents directly attached to the chromophore are called auxochromes. A strong correlation exists between the absorption maxima, λmax, and the structure of a conjugated π system. The Woodward–Fieser rules predict the value of λmax for a given structure by adding the contributions...
UV–Vis Spectroscopy: Molecular Electronic Transitions01:16

UV–Vis Spectroscopy: Molecular Electronic Transitions

In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this process,...
Chirality02:25

Chirality

Chirality is a term that describes the lack of mirror symmetry in an object. In other words, chiral objects cannot be superposed on their mirror images. For example, our feet are chiral, as the mirror image of the left foot, the right foot, cannot be superposed on the left foot.
Chiral objects exhibit a sense of handedness when they interact with another chiral object. For example, our left foot can only fit in the left shoe and not in the right shoe. Achiral objects — objects that have...
UV–Vis Spectrum01:30

UV–Vis Spectrum

When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.     
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar absorptivity (ε) or log ε on the y-axis (ordinate)...