Related Experiment Video
Updated: May 11, 2026

Measurement of the Hand Transmitted Vibration of the Human Hand Arm System During Operation of a Hand Tractor
Published on: June 16, 2021
Effect of coating over the handle of a drill machine on vibration transmissibility
1Department of Mechanical Engineering, Aligarh Muslim University, Aligarh-202002, UP, India.
Abstract:
This study was to see the effect of different coatings on the handle of hand-held drilling machines. Out of five different handles chosen for this study, including one handle uncoated. Root mean square (rms) values of the vibration levels (acceleration) were recorded at the surface of handle and wrist of the operators. Results showed that maximum vibrations were reduced by coating of handle coated with rubber sheet and Rexene (H4) followed by handle coated with cotton sandwiched between jeans cloth (H5). Equivalent vibrations transmitted through coating of handles coated with sponge and velvet (H2) and jute and cotton (H3) were of almost same magnitude and these two coated handles were able to reduce least vibration transmitted. Transmissibility of vibrations along dominant (Z) direction was analyzed using ANOVA. Results showed that coating on handles significantly affected vibration transmitted in Z direction. Vibration transmissibility ratios were found to be 0.354, 0.571, 0.408, 0.4326, and 0.3555 for handles H1, H2, H3, H4 and H5 respectively.
Related Concept Videos
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
Stress Concentrations in Circular Shafts
Characteristics of Dry Friction
Before the wheelbarrow starts moving, the static frictional force acts tangentially to the contact surface, opposing the force that is about to induce the motion. This frictional force prevents the...
Stresses in a Shaft
Applying equilibrium conditions to the QR segment establishes that the internal shearing forces within the...
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Factors Affecting Workability