Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Self-interaction chromatography in pre-packed columns: a critical evaluation of self-interaction chromatography
Natalie Rakel1, Kristina Schleining, Florian Dismer
1Section IV: Biomolecular Separation Engineering, Institute of Engineering in Life Sciences, Karlsruhe Institute of Technology, Engler-Bunte-Ring 1, 76131 Karlsruhe, Germany.
Abstract:
The characterization of protein-protein interactions is commonly conducted via self-interaction chromatography to describe magnitude and direction of the interactions with the resulting osmotic second virial coefficient (B22). However, the method is invasive and protein immobilization on the adsorber surface can influence the results obtained. In order to replace batch immobilization procedures followed by a column packing, direct on-column preparation was optimized in terms of protein immobilization under a continuous flow. Surface load was measured applying a novel method based on partial least squares analysis of spectral scans to reduce analytical error when determining the amount of immobilized protein. Subsequently influencing parameters such as the effects of absolute surface load, injected protein concentration and distribution of protein orientation were analyzed and system performance evaluated. The results disprove the consistency of the SIC method regarding the non-random orientation of proteins on adsorber particles. Thus the determined B22-values differ quantitatively from those determined with static light scattering. Furthermore, variations in immobilization conditions influence the results obtained. These results make clear that SIC does not fulfill the theoretical framework of B22-analysis. It is rather a qualitative measure of protein-protein interactions in the respective system used for experimentation.
Related Concept Videos
Principles Of Column Chromatography
Ion-Exchange Chromatography
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...