How far can the radiation dose be lowered in head CT with iterative reconstruction? Analysis of imaging quality and
Tung-Hsin Wu1, Sheng-Che Hung, Jing-Yi Sun
1Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan.
Objective:
To evaluate the imaging quality of head CT at lowered radiation dose by combining filtered back projection (FBP) and iterative reconstruction (IR) algorithms.
Methods:
Experimental group A (n = 66) underwent CT with 43 % tube current reduction, and group B (n = 58) received an equivalent reduced dose by lowering the tube voltage. An age- and sex-matched control group (n = 72) receiving the conventional radiation dose was retrospectively collected. Imaging for the control group was reconstructed by FBP only, while images for groups A and B were reconstructed by FBP and IR. The signal-to-noise ratios (SNRs), contrast-to-noise ratios (CNRs), sharpness, number of infarcts and severity of subcortical arteriosclerotic encephalopathy (SAE) were compared to assess imaging quality and diagnostic accuracy.
Results:
There were no significant differences in SNRs and CNRs between group A and the control group. There were significantly decreased SNRs and increased CNRs in group B. Image sharpness decreased in both groups. Correlations between detected infarcts and severity of SAE across FBP and IR were high (r = 0.73-0.93). Head diameter was the only significant factor inversely correlated with infratentorial imaging quality.
Conclusion:
Head CT with 43 % reduced tube current reconstructed by IR provides diagnostic imaging quality for outpatient management.
Key Points:
• Cranial CT using iterative reconstruction provides diagnostic images with 43 % mAs reduction. • Blurring of infratentorial images becomes evident using low-radiation head CT. • Head diameter was inversely correlated with imaging quality in the infratentorium. • Lowering tube kilovoltage requires a higher radiation dose to maintain image quality.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography