Related Experiment Video
Updated: May 11, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Assessment of eye and body dose for interventional radiologists, cardiologists, and other interventional staff
1Health Physics, Gartnavel Royal Hospital, Glasgow, UK. colin.martin@ggc.scot.nhs.uk
Abstract:
A dose limit for the eye of 20 mSv, as proposed by the ICRP, could be exceeded by interventional clinicians. Data on eye dose levels for interventional radiologists and cardiologists provided by medical physicists from hospitals around the UK have been collated. The results indicate that most hospitals would require one or more interventional clinicians to be classified and several would have exceeded a 20 mSv limit. Dose data in the literature have been reviewed to derive factors that might be used to predict eye dose levels based on dose per procedure or kerma-area product workload. These could be used in prior risk assessments to establish monitoring practice. An alternative approach to personnel dose monitoring in radiology applications using a collar dosimeter worn outside the lead apron as the first dosimeter is proposed. The collar dosimeter would provide an assessment of eye dose in terms of Hp(3) and body dose in terms of Hp(10), which could be divided by ten to provide an assessment of effective dose. If Hp(3) exceeded 1 mSv per month, regular monitoring with a head dosimeter would be recommended, and if Hp(10) exceeded 2 mSv per month, then an under-apron dosimeter should also be worn.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...