A sensitive method for the determination of levamisole in serum by electrochemiluminescence
Ying Xiao1, Jianping Li, Cong Fu
1College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, Guangxi, 541004, China.
Abstract:
A novel method was developed for the determination of levamisole by electrochemiluminescence. The method was based on electrochemiluminescence signal enhancement produced by Ru(bpy)(3)(2+), which reacted with the tertiary amine group of levamisole on a platinum electrode in 12 mmol/L borate buffer (pH 9). A linear relationship between the luminous intensity and concentration of levamisole in the range 0-1 × 10(-7) mol/L was obtained and the detection limit was 1.76 × 10(-11) mol/L. The method is sensitive, selective, simple and convenient. The method has been successfully applied to the analysis of levamisole in serum.