Related Experiment Video
Updated: May 11, 2026

High-resolution Functional Magnetic Resonance Imaging Methods for Human Midbrain
Published on: May 10, 2012
Computerized MRS voxel registration and partial volume effects in single voxel 1H-MRS
Hedok Lee1, Elisabeth Caparelli, Haifang Li
1Department of Anesthesiology, State University of New York at Stony Brook, Stony Brook, NY 11794, USA. hedoklee@gmail.com
Abstract:
Partial volume effects in proton magnetic resonance spectroscopy in the brain have been studied previously in terms of proper water concentration calculations, but there is a lack of disclosure in terms of voxel placement techniques that would affect the calculations. The purpose of this study is to facilitate a fully automated MRS voxel registration method which is time efficient, accurate, and can be extended to all imaging modalities. A total of thirteen healthy adults underwent single voxel 1H-MRS scans in 3.0T MRI scanners. Transposition of a MRS voxel onto an anatomical scan is derived along with a full calculation of water concentration with a correction term to account for the partial volume effects. Five metabolites (tNAA, Glx, tCr, mI, and tCho) known to yield high reliability are studied. Pearson's correlation analyses between tissue volume fractions and metabolite concentrations were statistically significant in parietal (tCr, Glx, and tNAA) lobe and occipital lobe (tNAA). MRS voxel overlaps quantified by dice metric over repeated visits yielded 60%~70% and coefficients of variance in metabolites concentration were 4%~10%. These findings reiterate an importance of considering the partial volume effects when tissue water is used as an internal concentration reference so as to avoid misinterpreting a morphometric difference as a metabolic difference.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET