Related Experiment Video
Updated: May 11, 2026

Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Poly(ethylene oxide)-bonded stationary phase for separation of inorganic anions in capillary ion chromatography
Roza Linda1, Lee Wah Lim, Toyohide Takeuchi
1Department of Chemistry, Faculty of Engineering, Gifu University, 1-1 Yanagido, Gifu 501-1193, Japan.
Abstract:
A tosylated-poly(ethylene oxide) (PEO) reagent was reacted with primary amino groups of an aminopropylsilica packing material (TSKgel NH2-60) in acetonitrile to form PEO-bonded stationary phase. The reaction was a single and simple step reaction. The prepared stationary phase was able to separate inorganic anions. The retention behavior of six common inorganic anions on the prepared stationary phase was examined under various eluent conditions in order to clarify its separation/retention mechanism. The elution order of the tested anions was iodate, bromate, bromide, nitrate, iodide, and thiocyanate, which was similar as observed in common ion chromatography. The retention of inorganic anions could be manipulated by ion exchange interaction which is expected that the eluent cation is coordinated among the PEO chains and it works as the anion-exchange site. Cations and anions of the eluent therefore affected the retention of sample anions. We demonstrated that the retention of the analyte anions decreased with increasing eluent concentration. The repeatability of retention time for the six anions was satisfactory on this column with relative standard deviation values from 1.1 to 4.3% when 10mM sodium chloride was used as the eluent. Compared with the unmodified TSKgel NH2-60, the prepared stationary phase retained inorganic anions more strongly and the selectivity was also improved. The present stationary phase was applied for the determination of inorganic anions contained in various water samples.
More Related Videos
Related Concept Videos
Ion-Exchange Chromatography
Ion Exchange
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Analyte Adsorption and Distribution

