Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer
Gasim I Gasim1, Imad R Musa, Mohamed T Abdien
1Faculty of Medicine, University of Khartoum, P,O, Box 102, Khartoum, Sudan.
Background:
During investigation and diagnosis of patients, accurate temperature measurement is of great importance. The advantages of tympanic membrane thermometry are speed (temperature reading available within seconds), safety, and ease of use. The aim of this study was to compare the accuracy of infrared tympanic thermometers in comparison to mercury thermometers in measurement of body temperature.
Methods:
Axillary and tympanic temperature was measured simultaneously in consecutive patients using mercury glass and infrared tympanic thermometers at Omdurman Hospital, Sudan during October 2012.
Results:
In total, temperature was measured in 174 patients, 95 of whom (54.6%) were male. The mean (SD) patient age and weight was 33.18 (25.07) years and 52.13 (69.85) kg. There was no significant difference in mean (SD) temperature measurement between mercury and infrared tympanic membrane thermometers, 37.29°C (0.91) versus 37.38°C (0.95), P = 0.373, respectively. There was a significant positive correlation between axillary and tympanic body temperature measurements (r = 0.697, P < 0.001). The mean difference between the two readings (with limits of agreements) was - 0.093 (-0.20; 0.02) °C.
Conclusion:
In this study, tympanic membrane thermometry is as reliable and accurate as axillary mercury glass thermometry. Thus, tympanic thermometry can be used in clinical practice, especially in the emergency setting, where ease of use and speed of obtaining the temperature reading are important.
More Related Videos
04:34Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
08:52Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...