Related Experiment Video
Updated: May 11, 2026

Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
Model complexity needed for quantitative analysis of high resolution isotope and concentration data from a
Dominik Eckert1, Shiran Qiu, Martin Elsner
1Center for Applied Geoscience, University of Tübingen, Hölderlinstraße 12, D-72074 Tübingen, Germany.
Abstract:
Separating microbial- and physical-induced effects on the isotope signals of contaminants has been identified as a challenge in interpreting compound-specific isotope data. In contrast to simple analytical tools, such as the Rayleigh equation, reactive-transport models can account for complex interactions of different fractionating processes. The question arises how complex such models must be to reproduce the data while the model parameters remain identifiable. In this study, we reanalyze the high-resolution data set of toluene concentration and toluene-specific δ(13)C from the toluene-pulse experiment performed by Qiu et al. (this issue). We apply five reactive-transport models, differing in their degree of complexity. We uniquely quantify degradation and sorption properties of the system for each model, estimate the contributions of biodegradation-induced, sorption-induced, and transverse-dispersion-induced isotope fractionation to the overall isotope signal, and investigate the error introduced in the interpretation of the data when individual processes are neglected. Our results show that highly resolved data of both concentration and isotope ratios are needed for unique process identification facilitating reliable model calibration. Combined analysis of these highly resolved data demands reactive transport models accounting for nonlinear degradation kinetics and isotope fractionation by both reactive and physical processes such as sorption and transverse dispersion.
More Related Videos
08:12An Introduction to Processing, Fitting, and Interpreting Transient Absorption Data
Published on: February 16, 2024
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Mass Analyzers: Common Types
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the method...
High-Resolution Mass Spectrometry (HRMS)
Qualitative Analysis
There are two main approaches to qualitative analysis:...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Analyzers: Overview