Related Experiment Video
Updated: May 11, 2026

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Diagnostic utility of a novel leadless arrhythmia monitoring device
Mintu P Turakhia1, Donald D Hoang, Peter Zimetbaum
1Veterans Affairs Palo Alto Health Care System, Palo Alto, CA, USA. mintu@stanford.edu
Abstract:
Although extending the duration of ambulatory electrocardiographic monitoring beyond 24 to 48 hours can improve the detection of arrhythmias, lead-based (Holter) monitors might be limited by patient compliance and other factors. We, therefore, evaluated compliance, analyzable signal time, interval to arrhythmia detection, and diagnostic yield of the Zio Patch, a novel leadless, electrocardiographic monitoring device in 26,751 consecutive patients. The mean wear time was 7.6 ± 3.6 days, and the median analyzable time was 99% of the total wear time. Among the patients with detected arrhythmias (60.3% of all patients), 29.9% had their first arrhythmia and 51.1% had their first symptom-triggered arrhythmia occur after the initial 48-hour period. Compared with the first 48 hours of monitoring, the overall diagnostic yield was greater when data from the entire Zio Patch wear duration were included for any arrhythmia (62.2% vs 43.9%, p <0.0001) and for any symptomatic arrhythmia (9.7% vs 4.4%, p <0.0001). For paroxysmal atrial fibrillation (AF), the mean interval to the first detection of AF was inversely proportional to the total AF burden, with an increasing proportion occurring after 48 hours (11.2%, 10.5%, 20.8%, and 38.0% for an AF burden of 51% to 75%, 26% to 50%, 1% to 25%, and <1%, respectively). In conclusion, extended monitoring with the Zio Patch for ≤14 days is feasible, with high patient compliance, a high analyzable signal time, and an incremental diagnostic yield beyond 48 hours for all arrhythmia types. These findings could have significant implications for device selection, monitoring duration, and care pathways for arrhythmia evaluation and AF surveillance.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...