Related Experiment Video
Updated: May 11, 2026

Microscale Vortex-assisted Electroporator for Sequential Molecular Delivery
Published on: August 7, 2014
Electroporation of intracellular liposomes using nanosecond electric pulses--a theoretical study
Lea Retelj1, Gorazd Pucihar, Damijan Miklavcic
1Faculty of Electrical Engineering, University of Ljubljana, Ljubljana SI-1000, Slovenia. lea.retelj@fe.uni-lj.si
Abstract:
Nanosecond (ns) electric pulses of sufficient amplitude can provoke electroporation of intracellular organelles. This paper investigates whether such pulses could provide a method for controlled intracellular release of a content of small internalized artificial lipid vesicles (liposomes). To estimate the pulse parameters needed to selectively electroporate liposomes while keeping the plasma and nuclear membranes intact, we constructed a numerical model of a biological cell containing a nucleus and liposomes of different sizes (with radii from 50 to 500 nm), which were placed in various sites in the cytoplasm. Our results show that under physiological conditions selective electroporation is only possible for the largest liposomes and when using very short pulses (few ns). By increasing the liposome interior conductivity and/or decreasing the cytoplasmic conductivity, selective electroporation of even smaller liposomes could be achieved. The location of the liposomes inside the cell does not play a significant role, meaning that liposomes of similar size could all be electroporated simultaneously. Our results indicate the possibility of using ns pulse treatment for liposomal drug release.